Before you begin. This procedure is general reference information, not professional advice. Equipment varies by manufacturer, model, and year. Always follow the documentation supplied with your equipment — where it differs from this page, follow the manufacturer. Verify that you have the tools, the working conditions, and the ability to do this task safely. If anything is unclear, if the equipment is damaged, or if the task exceeds your experience, stop and use a qualified professional. You are responsible for your own safety and for the outcome. This site accepts no liability for any loss, damage, or injury arising from the use of this information.
Specifications marked unverified could not be traced to a manufacturer source. Do not rely on them — obtain the value from your equipment documentation.
Summary
Every dehumidifier carries a pint-per-day number, and matching that number to your room takes two facts: the room's floor area and how damp the room is without a dehumidifier running. ENERGY STAR publishes a chart that crosses two room-size groups with three dampness levels to give a recommended pint range. This page walks through measuring the room, judging its condition, and reading that chart, then helps you decide between a portable unit and a whole-home, duct-connected system.
The trap is the number itself. The U.S. Department of Energy changed the official capacity test in 2019, from 80-degree air to 65-degree air, so a pint rating from 2019 or earlier and a pint rating from 2020 or later are not the same measurement, even printed on an identical-looking box. This page gives ENERGY STAR's own old-to-new correlation table so a rating from either side of that change can be read correctly, and says plainly where it stops: an odd-shaped room, an open floor plan, or a whole-home duct system needs a professional, not this chart.
Necessary equipment
| Item | Note |
|---|---|
| Tape measure | Measure the length and the width of the room in feet. |
| Pencil and paper | Record your measurements, your room's condition, and the chart range. |
| Rating plate or product listing for the dehumidifier optional | The rating plate or the product page names the pint number and the date, if the source names a date. |
Find the test year behind your rating
Estimated 5 min
DO NOT COMPARE A DEHUMIDIFIER RATING FROM BEFORE 2020 TO A RATING FROM 2020 OR LATER.
The government changed the test in 2019. The wrong comparison hides the correct size.
- Find the pint-per-day number on the dehumidifier or on the chart you plan to use.<1mReport a problem with step 1, Find the test year behind your rating
- Find the date of that number, if the source names one.<1mReport a problem with step 2, Find the test year behind your rating
- Treat a rating from 2019 or earlier as a different measurement from a rating for 2020 or later.2mReport a problem with step 3, Find the test year behind your rating
- The U.S. Department of Energy changed the dehumidifier capacity test in 2019.
- The new test uses the air at 65 degrees F.
- The old test used air at 80 degrees F.
- Cool air holds less moisture than warm air.
- The same dehumidifier gives a lower number under the new test.
- A lower number after 2019 does not mean a smaller or a weaker machine.
- Convert an old rating to an approximate new rating with this table, if you compare the two.2mReport a problem with step 4, Find the test year behind your rating
- A 30-pint rating from 2019 or earlier is about 20 pints under the new test.
- A 40-pint rating from 2019 or earlier is about 25 pints under the new test.
- A 50-pint rating from 2019 or earlier is about 30 pints under the new test.
- A 55-pint rating from 2019 or earlier is about 30 to 35 pints under the new test.
- A 60-pint rating from 2019 or earlier is about 35 pints under the new test.
- A 70-pint rating from 2019 or earlier is about 40 to 45 pints under the new test.
- A 90-pint rating from 2019 or earlier is about 55 pints under the new test.
- ENERGY STAR states that the actual change varies by model.
- Judge a replacement by the water you empty each day, if you replace an old dehumidifier.<1mReport a problem with step 5, Find the test year behind your rating
- ENERGY STAR gives this method instead of a direct comparison of the old number and the new number.
Measure the room
Estimated 2 min
- Measure the length of the room in feet from wall to wall.<1mReport a problem with step 1, Measure the room
- Measure the width of the room in feet from wall to wall.<1mReport a problem with step 2, Measure the room
- Multiply the length and the width to find the area in square feet.<1mReport a problem with step 3, Measure the room
- A room 12 feet long and 15 feet wide has an area of 12 x 15 = 180 square feet.
Judge the room without a dehumidifier running
Estimated 2 min
- Judge the room by how it feels and smells without a dehumidifier running.2mReport a problem with step 1, Judge the room without a dehumidifier running
- Slightly to moderately damp: the room smells musty at times.
- Slightly to moderately damp is 50 to 75 percent relative humidity.
- Very damp: the room always feels and smells damp. Wet patches show on the walls or the floor.
- Very damp is 75 to 90 percent relative humidity.
- Wet: water forms on the walls or the floor.
- Wet is 90 to 100 percent relative humidity.
Find the capacity range for your room
Estimated 2 min
- Match your room area to a size group: under 2,000 square feet, or 2,000 square feet and over.<1mReport a problem with step 1, Find the capacity range for your room
- Read the recommended pint-per-day range for your size group and the condition you judged before.1mReport a problem with step 2, Find the capacity range for your room
- Slightly to moderately damp, under 2,000 square feet: 20 to 30 pints per day.
- Slightly to moderately damp, 2,000 square feet and over: 30 pints per day or more.
- Very damp, under 2,000 square feet: 25 to 40 pints per day.
- Very damp, 2,000 square feet and over: 40 pints per day or more.
- Wet, under 2,000 square feet: 30 to 50 pints per day.
- Wet, 2,000 square feet and over: 50 pints per day or more.
- Choose a dehumidifier with a pint rating at or above the top of your range.<1mReport a problem with step 3, Find the capacity range for your room
- A higher rating takes out moisture faster.
- ENERGY STAR states that an oversized dehumidifier costs less than an undersized dehumidifier.
Choose a portable or a whole-home dehumidifier
Estimated 2 min
No tier-1 source was found for this value. Take it from the documentation supplied with your equipment.
- Choose a portable dehumidifier for one room with a door that closes.<1mReport a problem with step 1, Choose a portable or a whole-home dehumidifier
- Consider a whole-home dehumidifier for a humid house with central air conditioning.<1mReport a problem with step 2, Choose a portable or a whole-home dehumidifier
- ENERGY STAR describes this case as a house with central air conditioning.
- The relative humidity in the house is above 55 percent throughout.
DO NOT SIZE OR INSTALL A WHOLE-HOME DEHUMIDIFIER YOURSELF.
A professional sizes and fits a whole-home dehumidifier to your duct system. A wrong fit can let moisture reach the building frame.
- Hire a professional to fit a whole-home dehumidifier to your ducts.<1mReport a problem with step 3, Choose a portable or a whole-home dehumidifier
- Find the dehumidifier's minimum rated temperature before you buy it for a cold space.<1mReport a problem with step 4, Choose a portable or a whole-home dehumidifier
- A standard compressor dehumidifier can form frost when the air is below 65 degrees F.
- This operating limit is not the test temperature named earlier in this page.
- The two facts use the same number for different reasons.
- Choose a dehumidifier rated for lower temperatures for a cold garage or an unheated space.
- Find the water removal method before you buy: a bucket you empty, or a hose to a drain.<1mReport a problem with step 5, Choose a portable or a whole-home dehumidifier
- You must empty a bucket by hand.
- A full bucket stops the dehumidifier automatically.
- A hose sends water to a floor drain or a sump pump.
- You do not need to empty a hose.
Terminology
This page uses one term for each item and holds it throughout, as ASD-STE100 requires. Equipment sellers and other guides use the names below for the same parts.
- dehumidifier capacity
- Also called: pint rating, dehumidifier size, how many pints do I need, 50 pint vs 30 pint dehumidifier, dehumidifier pints per day
- relative humidity
- Also called: room humidity, how damp is my room, RH percentage, humidity level
- whole-home dehumidifier
- Also called: ducted dehumidifier, central dehumidifier, whole house dehumidifier, HVAC dehumidifier
- portable dehumidifier
- Also called: room dehumidifier, standalone dehumidifier, bucket dehumidifier
- room floor area
- Also called: room size, square footage, square feet, floor space
When to use a professional
Call a heating and cooling contractor to size and install a whole-home dehumidifier. Call the manufacturer for a room with an open floor plan, an unusual shape, or a connection to another room. Call the manufacturer if your room's condition is worse than the wet row in the chart.
Common questions
What size dehumidifier do I need?
It depends on your room's floor area and how damp the room is without a dehumidifier running. ENERGY STAR publishes a chart with two room-size groups (under 2,000 square feet and 2,000 square feet and over) crossed with three dampness levels, each with a recommended pint-per-day range. Measure your room, judge its condition, and read the range from the chart. Choose a unit at or above the top of the range, because ENERGY STAR says it is better to oversize than to undersize.
Why did the pint rating on dehumidifiers get smaller a few years ago?
The U.S. Department of Energy changed the official test in 2019. The old test rated a dehumidifier's moisture removal in 80-degree air; the new test uses 65-degree air, which is closer to a real basement. Cooler air holds less water, so the same physical machine reports a lower pint number under the new test. A lower number does not mean a smaller or weaker dehumidifier — it means a different, more realistic test.
Is a 50-pint dehumidifier from 2015 the same as a 50-pint dehumidifier today?
No. The 2015 unit was rated under the old, warmer test. ENERGY STAR's own correlation table puts a pre-2020 50-pint rating at about 30 pints under the current test. If you are comparing an old unit to a new one, use that table, or judge the old unit by how much water you actually empty from it each day rather than by the number printed on it.
My basement smells musty and has laundry drying in it. What size do I need?
Laundry drying indoors is one of the conditions ENERGY STAR lists under its wettest category, alongside walls or floors that sweat or visible seepage. For that condition, the chart recommends 30 to 50 pints per day in a room under 2,000 square feet, and 50 pints per day or more in a larger space. A musty smell alone, with no standing moisture, is the lighter "slightly to moderately damp" category instead.
Should I buy a portable dehumidifier or a whole-home system?
A portable dehumidifier is the usual choice for a single room or a basement with a door that closes. A whole-home, duct-connected dehumidifier is worth considering if your house has central air conditioning and stays above about 55 percent relative humidity throughout, but ENERGY STAR is clear that it needs a professional to size and install it correctly. This page does not size a duct system.
Can I use a regular dehumidifier in an unheated garage?
Check its rated minimum operating temperature first. ENERGY STAR warns that frost can form on a standard compressor dehumidifier's coils once the air drops below 65 degrees F, which stops it removing moisture properly. That is a separate fact from the 65-degree test temperature discussed elsewhere on this page — one is about where the machine is used, the other is about how its box number was measured. For a cold space, look for a unit rated for lower temperatures.
What does "pints per day" actually measure?
It is the amount of water the dehumidifier removes from the air over 24 hours under the government's test conditions, not a tank size or a bucket size. ENERGY STAR describes it as the dehumidifier's "size" for shopping purposes. Two dehumidifiers with the same pint rating, tested under the same current procedure, remove moisture at roughly the same rate.
Related procedures
- How to find and record the model and serial number of every appliance in the house
- Why is my dehumidifier running but not collecting water?
- What humidity should I set my humidifier or dehumidifier to, and how do I check it actually worked
- What the error code on my dehumidifier means
- What size air cleaner (by CADR) do I need for my room?
- How to connect and unclog a dehumidifier drain hose so it doesn't fill the bucket
- Clean and disinfect a room humidifier and choose the water to fill it with
Sources
Every specification on this page is traced to one of these sources. Tier 1 is a manufacturer document, a published standard, or a government safety authority. See Standards for the full tiering rule.
- Tier 1Dehumidifiers
- Tier 1Dehumidifier Testing and Capacity
Revision history
Current version 1 · updated 2026-08-04 · next review due 2027-08-04
- v1 · 2026-08-04First draft. Sizing chart and the 2019 test-procedure change both sourced to ENERGY STAR (energystar.gov), read directly on 2026-08-04. The old-to-new capacity correlation table is quoted from ENERGY STAR's own published table. Whole-home duct sizing publishes as consult-a-contractor rather than a number; the operating-temperature spec is the only verified numeric specification and is kept explicitly distinct from the unrelated 65-degree test-condition fact.
Corrections to this page are listed in the public corrections log. Reports that are credible and not yet verified are listed in the public errata register, and an open one renders above the step it concerns.
Comments and corrections
Found an error? A correction with a manufacturer source is applied and logged publicly. You can also write to corrections@fixchecklist.com.
Every step above carries its own report control, which tags the report with that step so a correction reaches the right place. For anything about the procedure as a whole — the order of the sections, a step that is missing, something that did not match your equipment — use this: report something about this whole procedure.