Check Continuity and Test a Fuse with a Multimeter

A de-energized beep test for a power cord, a switch, a fuse or a light bulb, using the continuity function on any digital multimeter
ApplicabilitySmall unplugged household items only: a lamp or appliance power cord, an in-line or appliance switch, a cartridge, blade or glass fuse removed from its holder, and an incandescent light bulb filament. Any digital multimeter with a continuity or resistance function. Not for a wall switch, a wall receptacle, a circuit breaker, or any wiring inside a building's electrical system.
Task time14 min to 23 min editorial estimate, not a measurement
PersonnelOne
Revisionv1 · 2026-08-04
BEFORE YOU BEGIN

Before you begin. This procedure is general reference information, not professional advice. Equipment varies by manufacturer, model, and year. Always follow the documentation supplied with your equipment — where it differs from this page, follow the manufacturer. Verify that you have the tools, the working conditions, and the ability to do this task safely. If anything is unclear, if the equipment is damaged, or if the task exceeds your experience, stop and use a qualified professional. You are responsible for your own safety and for the outcome. This site accepts no liability for any loss, damage, or injury arising from the use of this information.

Specifications marked unverified could not be traced to a manufacturer source. Do not rely on them — obtain the value from your equipment documentation.

Summary

Continuity is the one multimeter test almost every household job needs, because it answers a single question: does electricity have an unbroken path from one end of this part to the other? A blown fuse, a cut cord, a failed switch and a dead bulb filament all show the same result on the meter — no continuity — and the same beep tells you a fuse, a switch, a cord or a bulb is still good. This page covers the one setup and the one test, done the same way on any of those four items.

Everything here is done with the item unplugged and the part removed or isolated from the rest of its circuit. That is not a suggestion. Fluke, the maker of the test instrument this page is written around, says plainly to turn off circuit power before testing resistance or continuity, and a continuity or resistance test run on a circuit that still has power can damage the meter and shock you. This page does not cover a wall switch, a wall receptacle, or any wiring inside a building's electrical system — that work needs a qualified electrician and a different set of tools.

Safety

WARNING

DISCONNECT THE ITEM FROM ITS ELECTRICAL SUPPLY BEFORE A CONTINUITY TEST.
A continuity test on a circuit that still has power can damage the meter. It can also give you an electric shock.

Necessary equipment

ItemNote
Digital multimeterThe multimeter must have a continuity function or a resistance function.
Small screwdriver optionalSome fuse holders and switch housings need a screwdriver to open.
Flashlight optionalThe space around the item is often dark.
Pen and paper optionalRecord the date and the result of the test.
Replacement fuse, switch, cord or bulb materialGet the correct replacement part before you start. A failed part needs replacement, not repair.

Start

Estimated 4 min to 6 min

NOTEThe continuity function is the same idea on every multimeter. The button and the symbol are different for each model.
  1. Read the manual for your own multimeter.
    • The continuity function is different for each model.
    • Some multimeters need a button press to turn on the continuity function.
    3mReport a problem with step 1, Start
WARNING

DO NOT USE A DAMAGED METER OR DAMAGED TEST LEADS.
Exposed metal on a lead or a crack in the meter case can give you an electric shock.

  1. Examine the multimeter and the test leads for damage.
    • Look for a crack in the case.
    • Look for exposed metal on a lead.
    <1mReport a problem with step 2, Start
  2. Gather the item for the test.
    • This procedure covers a power cord, a switch, a fuse, and a light bulb.
    • This procedure does not cover a wall switch or the wiring in a building.
    <1mReport a problem with step 3, Start

Disconnect the item

Estimated 3 min to 8 min

NOTEEvery part of this test happens with no power connected to the item.
State of the item's electrical supply required for a continuity test
Manufacturer or standard verified
DISCONNECTED

Source: How to Use a Multimeter: A Comprehensive Guide · tier 1 · accessed 2026-08-04

  1. Disconnect the item from its electrical supply.
    • Remove the plug from the wall outlet.
    • Remove the batteries from a battery-powered item.
    <1mReport a problem with step 1, Disconnect the item
WARNING

LET A RECENTLY USED BULB COOL BEFORE YOU TOUCH IT.
A hot bulb can burn your skin.

  1. Let a recently used light bulb cool before you touch it.
    1mReport a problem with step 2, Disconnect the item
NOTICE

ISOLATE THE COMPONENT FROM THE REST OF THE CIRCUIT BEFORE THE TEST.
A component still connected to other parts can give you a false reading.

  1. Remove the component from its holder or from its circuit.
    • Remove a fuse from its holder.
    • Disconnect a switch from its wires, or remove it from its housing.
    • Disconnect both ends of a cord from other equipment.
    • Remove a bulb from its socket.
    1mReport a problem with step 3, Disconnect the item
  2. Examine the item for melted plastic, a scorched mark, or a broken part.
    <1mReport a problem with step 4, Disconnect the item
  3. If you find damage, stop this procedure.
    • Speak to a qualified technician about a damaged item.
    <1mReport a problem with step 5, Disconnect the item

Set the continuity function

Estimated 2 min to 2 min

Multimeter jack for the black test lead during a continuity test
Manufacturer or standard verified
COM

Source: A Guide to Continuity Testing with a Multimeter · tier 1 · accessed 2026-08-04

Multimeter jack for the red test lead during a continuity test
Manufacturer or standard verified

Source: A Guide to Continuity Testing with a Multimeter · tier 1 · accessed 2026-08-04

Multimeter display in continuity mode with the probes apart
Manufacturer or standard verified
OL

Source: A Guide to Continuity Testing with a Multimeter · tier 1 · accessed 2026-08-04

Resistance value at which your multimeter beeps in continuity mode
Unverified — do not rely on this value
CONSULT THE DOCUMENTATION FOR YOUR OWN MULTIMETER. THE THRESHOLD VARIES BY MODEL AND BY RANGE SETTING.

No tier-1 source was found for this value. Take it from the documentation supplied with your equipment.

  1. Turn the dial to the continuity function.
    • Many multimeters combine this function with the resistance function.
    • Press the continuity button if your multimeter needs one.
    <1mReport a problem with step 1, Set the continuity function
  2. Insert the black test lead into the COM terminal.
    <1mReport a problem with step 2, Set the continuity function
  3. Insert the red test lead into the VΩ terminal.
    <1mReport a problem with step 3, Set the continuity function
  4. Separate the two probes and read the display.
    • The display can show OL with the probes apart.
    • This reading shows the meter is ready for the test.
    <1mReport a problem with step 4, Set the continuity function

Run the test

Estimated 2 min to 2 min

  1. Touch one probe to one end of the component.
    <1mReport a problem with step 1, Run the test
  2. Touch the other probe to the other end of the component.
    • The order of the two probes does not matter for this test.
    • Press each probe against a metal part.
    • Do not press a probe against insulation.
    <1mReport a problem with step 2, Run the test
  3. Listen for a sound from the multimeter.
    <1mReport a problem with step 3, Run the test
  4. Read the display of the multimeter.
    <1mReport a problem with step 4, Run the test
  5. Repeat the test once more.
    • The two results must be the same.
    <1mReport a problem with step 5, Run the test
  6. Remove the probes from the component.
    <1mReport a problem with step 6, Run the test

Read the result

Estimated under a minute

Multimeter response to a component with continuity
Manufacturer or standard verified
A BEEP

Source: A Guide to Continuity Testing with a Multimeter · tier 1 · accessed 2026-08-04

Multimeter response to a component with no continuity
Manufacturer or standard verified
NO BEEP

Source: A Guide to Continuity Testing with a Multimeter · tier 1 · accessed 2026-08-04

  1. If the multimeter beeps, the component has continuity.
    • A fuse with continuity is a good fuse.
    • A closed switch has continuity.
    • A cord or a bulb with continuity has no break.
    <1mReport a problem with step 1, Read the result
  2. If the multimeter does not beep, the component has no continuity.
    • A fuse with no continuity is a blown fuse.
    • An open switch, or a faulty switch, has no continuity.
    • A cord or a bulb with no continuity has a break.
    <1mReport a problem with step 2, Read the result

Finish the test

Estimated 2 min to 4 min

Order to remove the test leads from the multimeter after a test
Manufacturer or standard verified
RED LEAD FIRST, THEN THE BLACK LEAD

Source: A Guide to Continuity Testing with a Multimeter · tier 1 · accessed 2026-08-04

Current rating for a replacement fuse
Unverified — do not rely on this value
CONSULT THE DOCUMENTATION FOR YOUR OWN ITEM. USE THE EXACT TYPE AND RATING IT SPECIFIES.

No tier-1 source was found for this value. Take it from the documentation supplied with your equipment.

  1. Remove the red test lead from the multimeter first.
    <1mReport a problem with step 1, Finish the test
  2. Remove the black test lead from the multimeter second.
    <1mReport a problem with step 2, Finish the test
  3. Turn the multimeter off.
    • Fluke tells you to turn the meter off to save the battery.
    <1mReport a problem with step 3, Finish the test
  4. Do not use a component with no continuity.
    • Replace a blown fuse with the exact type and rating for your item.
    • Replace a broken switch, cord, or bulb before you use the item again.
    <1mReport a problem with step 4, Finish the test
  5. Reassemble the item.
    • Put a good fuse back in its holder.
    • Reconnect a switch to its wires, or put it back in its housing.
    • Screw a good bulb back into its socket.
    1mReport a problem with step 5, Finish the test
  6. Record the date and the result of the test.
    • A record helps you track a part that fails again.
    <1mReport a problem with step 6, Finish the test

Terminology

This page uses one term for each item and holds it throughout, as ASD-STE100 requires. Equipment sellers and other guides use the names below for the same parts.

continuity
Also called: continuity test, continuity check, beep test, continuity setting, continuity mode, multimeter beep test
multimeter
Also called: voltmeter, volt meter, DMM, tester, digital multimeter, electrical tester
open circuit
Also called: no continuity, broken circuit, OL reading, broken wire, blown fuse reading
closed circuit
Also called: good continuity, complete circuit, unbroken wire
test lead
Also called: probe, meter lead, multimeter wire, meter probe
fuse
Also called: blown fuse, cartridge fuse, blade fuse, glass fuse
meter terminal
Also called: COM jack, VΩ jack, common jack, ground jack, black probe jack, negative jack, input jack

When to use a professional

This procedure is for small unplugged items only. It does not cover a wall switch, a wall receptacle, or wiring inside a building's electrical system. Speak to a qualified electrician for that work.

Stop if the item shows melted plastic, a scorched mark, or a broken part. Speak to a qualified technician about a damaged item.

This procedure checks one component for continuity. It does not find why a fuse or a switch failed. A new fuse can fail again soon after you fit it. If this happens, speak to a qualified technician.

This procedure does not cover a multimeter measurement on a circuit that still has power. Consult the documentation for your own multimeter, or speak to a qualified electrician, for a measurement on a live circuit.

Common questions

How do I test a fuse with a multimeter?

Remove the fuse from its holder so it is fully isolated, set the multimeter to the continuity function, and touch one probe to each end of the fuse. Fluke's own guidance is direct: a good fuse should show continuity, meaning the meter beeps and shows a low reading. No beep, or a display reading OL, means the fuse is blown. Never test a fuse while it is still in a live circuit.

What is the multimeter continuity setting, and how do I turn it on?

It is a dial position, usually shown by a sound-wave or diode-like symbol, often sharing a spot on the dial with the resistance (Ω) function. Fluke's guide notes that some models need you to press a separate continuity button to activate it once the dial is in position. Check your own multimeter's manual, since the exact symbol and any button vary by model.

How do I check if a wire is broken?

Disconnect both ends of the cord or wire from anything else, then run the same continuity test across its full length: one probe at each end. A beep and a low reading mean the conductor inside is unbroken end to end. No beep, or an OL reading, means there is a break somewhere along the wire, even if the outer insulation looks fine.

What does the multimeter beep actually mean?

It means the meter found a complete, low-resistance path between its two probes. Fluke's continuity guide puts it plainly: the meter emits a beep if a complete path is detected, and it does not beep if the circuit is open. The beep lets you keep your eyes on the probes and the component instead of watching a numeric display.

What does OL mean on my multimeter?

OL stands for overload, and in continuity or resistance mode it means the meter is reading a resistance too high to measure — in practice, an open circuit. You will see it on a healthy meter with the probes held apart, and you will see it again on a component with no continuity, such as a blown fuse or a broken wire.

Can I test continuity on something that is still plugged in?

No. Fluke's own safety guidance is unambiguous: turn off circuit power before testing resistance or continuity, and prioritize safety to avoid electric shock or damage to your equipment. A continuity test relies on the meter's own small internal battery, and outside power on the same terminals can damage the meter and shock you. Unplug the item, and remove batteries from a battery-powered item, before you connect a single probe.

The fuse tests good but the item still does not work. What now?

A continuity test only tells you whether that one part is intact — it does not diagnose the rest of the item. A cord, a switch, or an internal connection could still be at fault, and if a new fuse blows again shortly after replacement, that usually points to a fault elsewhere in the circuit rather than a second bad fuse. Speak to a qualified technician rather than keep replacing parts.

Sources

Every specification on this page is traced to one of these sources. Tier 1 is a manufacturer document, a published standard, or a government safety authority. See Standards for the full tiering rule.

  1. Tier 1A Guide to Continuity Testing with a MultimeterFluke Corporation · accessed 2026-08-04 · re-verification due 2027-01-31
  2. Tier 1How to Use a Multimeter: A Comprehensive GuideFluke Corporation · accessed 2026-08-04 · re-verification due 2027-01-31
  3. Tier 1Guide to Digital Multimeter SafetyFluke Corporation · accessed 2026-08-04 · re-verification due 2027-01-31
  4. Tier 1How to Check a Fuse with a MultimeterFluke Corporation · accessed 2026-08-03 · re-verification due 2027-01-30

Revision history

Current version 1 · updated 2026-08-04 · next review due 2027-08-04

  1. v1 · 2026-08-04First draft. Method, probe-jack assignment, mode selection, beep/no-beep interpretation, the OL display, and the lead-removal order are sourced from Fluke Corporation's own 'A Guide to Continuity Testing with a Multimeter', read at the first-party URL via a direct HTTP GET and via WebFetch on 2026-08-04 (both HTTP 200, contents agree). The requirement to disconnect the item from its electrical supply before any continuity or resistance test rests on Fluke's 'How to Use a Multimeter: A Comprehensive Guide' safety tips ('Always turn off circuit power and discharge all high-voltage capacitors before testing resistance, continuity, diodes, or capacitance.'), and renders as the page-level hazard, above every step, per rule 4. The instruction never to use a damaged meter or damaged test leads rests on Fluke's 'Guide to Digital Multimeter Safety'. The existing tier-1 source fluke-how-to-check-fuse-with-multimeter, already registered in data/sources.json for test-a-dryer-thermal-fuse-for-continuity, is reused rather than re-staged. Scope is deliberately narrow: a power cord, an in-line or appliance switch, a fuse removed from its holder, and a light bulb, all fully disconnected and isolated before any probe touches them. The page explicitly excludes a wall switch, a wall receptacle, and any building wiring, and routes that work to a qualified electrician in the professional boundary, keeping the record inside Phase 1 (no mains voltage, line voltage, breaker panel, or live-circuit work). No safety-critical numeric value is published: the resistance threshold at which a given meter beeps and the current rating for a replacement fuse both vary by model or by item and publish as an instruction to consult the manufacturer, with no digit in either value. Sources are staged in data/sources-additions-check-continuity-with-a-multimeter.json and are not yet admitted to data/sources.json; check 3 will hold this record until scripts/sources_admit.py runs.

Corrections to this page are listed in the public corrections log. Reports that are credible and not yet verified are listed in the public errata register, and an open one renders above the step it concerns.

Comments and corrections

Found an error? A correction with a manufacturer source is applied and logged publicly. You can also write to corrections@fixchecklist.com.

Every step above carries its own report control, which tags the report with that step so a correction reaches the right place. For anything about the procedure as a whole — the order of the sections, a step that is missing, something that did not match your equipment — use this: report something about this whole procedure.

The comment system is not connected yet. Comments are stored in GitHub Discussions through Giscus, outside this site, so that a redeploy cannot destroy them.